Docs
How the UINCS trace calculator works — inputs, formulas and limits.
Inputs and units
- Sheet resistance (Ω/sq) at the thickness you actually print. Datasheets often give mΩ/sq at a stated thickness, sometimes per 25 µm (1 mil): divide mΩ by 1000, and scale by reference thickness ÷ your thickness if yours differs.
- Length and width of the trace in millimetres. Only their ratio matters for resistance; the absolute size is used for the stretched size and the CSV.
- Strain in percent, 0 to 1000. 0 % is unstretched, 100 % is twice the original length.
- Current in milliamps (optional) for the voltage drop and power. Max resistance in ohms (optional) for the width check.
Formulas
- Squares N = length ÷ width. Unstretched resistance R0 = sheet resistance × N.
- Strain ε = percent ÷ 100.
- Constant volume: the conductor keeps its volume and shrinks evenly across, so length × (1 + ε), width and thickness ÷ √(1 + ε), and R = R0 × (1 + ε)². This is the lower bound for a trace that does not crack.
- Gauge factor: R = R0 × (1 + GF × ε), with GF = (ΔR ÷ R0) ÷ ε from your own stretch test. Constant volume at small strain is the same as GF = 2.
- Voltage drop V = I × R, power P = I² × R, at the chosen strain.
- Minimum width = sheet resistance × length × (R ÷ R0 at that strain) ÷ max resistance.
What the numbers leave out
- Real stretchable conductors — silver flake in elastomer, liquid metal, carbon blends — rarely follow constant volume. Flakes separate and micro-cracks open, so resistance usually rises faster, and it can jump when a crack crosses the trace.
- Resistance also depends on how many times and how fast you stretch: first-cycle rise, hysteresis and long-term drift are not modelled.
- Contact resistance at pads, connectors and vias is not included. Add it yourself to the result.
- Use UINCS to size traces and compare options, then confirm on printed samples.
Saved traces and CSV
- In /app, set the inputs, type a name and choose Save. You can keep up to 30 traces; names are up to 60 characters and must be different.
- Load puts a saved trace's inputs back into the form. Delete removes it. Your last inputs are kept too.
- Download CSV gives one row per saved trace: inputs, squares, R0, model, resistance at strain, change, current, drop and power.
- Cells that start with =, +, -, @, tab or carriage return get a leading apostrophe so a spreadsheet does not run them as formulas.
Account and workspace
- Choose Sign up, then enter your name, email and a password with at least 8 characters, one letter and one number.
- You land in your workspace at /app. Saved traces are kept in this browser (localStorage) under your account. Clearing site data removes them, so download a CSV now and then.
- Use Log out in the top bar when you are done on a shared device. To delete your account, email [email protected].
Account API
- POST /api/auth/signup with JSON { name, email, password } → 201 and a session cookie; 409 if the email is taken, 400 on invalid input.
- POST /api/auth/login with JSON { email, password } → 200 and a session cookie; 401 on a wrong password, 429 after too many tries.
- GET /api/auth/me → 200 with the signed-in user, or 401 when signed out. POST /api/auth/logout ends the session.
- Requests that change data must come from the same origin (cookie session, no API keys). The calculator itself has no API — it runs in your browser.
UINCS works out textbook formulas from the values you enter. It is an estimate for sizing traces, not test data — confirm on printed samples.